Time to Re-Evaluate Your Gaging?
Let’s say you’ve been making the same part for decades, running hundreds or
thousands of parts every day, from the same machines, using the same process and
the same gaging purchased when the process was started. If this is the case,
then you’re not alone. It’s also not uncommon to find that manufacturing
tolerances have been tightened as the demand to run parts more efficiently
increased. Perhaps when the parts were first made, the bearing diameter was
±0.002", then it was changed to ±0.001", and now you are expected to hold
±0.0005"—all with the same machines and the same gages that were bought years
ago.
Again, this is not an infrequent situation. Although it may not always be a
problem, it is a clear signal that you should take another look at your gaging.
Gages designed to measure to thousandths are substantially better than those
built for lesser tolerances. With a little tender care, these gages are often
able to measure a few more ten-thousandths than if they aren't properly cared
for. Here are some pointers for ensuring that the performance of your gaging can
keep up with the demands of changing part tolerances.
First, check the readout device. Maybe the gages were originally supplied with
dial indicators having grads of 0.0002" or 0.0001". For a ±0.0005" tolerance,
this will not be a good fit. The operator will have difficulty discriminating
the tolerance band and the indicator will not use enough of the dial span.
Change to a 0.0001" grad indicator or, better yet, put in a digital indicator
having 50 microinches or 20 microinches digital resolution. Now the operator can
resolve the measurement sufficiently to make better decisions.
This method is not the catch-all for tighter tolerances, however. The gage needs
to be capable of doing the task, or else there will be far too many repeat
errors for the gage to be useful.
Checking with the gage manufacturer will help you understand what the real
limits of your gages are before you go too far down this path. Maybe the gages
were not designed to meet the new tolerance requirements. This could mean that
an investment in new gaging is required. However, for some gaging, such as fixed
body gages (air plugs or mechanical plug gages), body clearance will be the
deciding factor on whether the gaging is capable. The gage may need to be
reworked to reduce the body clearance and thus reduce the amount of
centralization error in the plug. This reduction will greatly improve the
repeatability and performance of the tooling.
Often with this type of gaging, a simple added piece of fixturing can remove
most of the operator influence on the measurement. For example, with the same
fixed plug gage, the addition of a stop collar can help square up the part and
bring the measuring contacts to the same spot, thus greatly reducing the
influence of part irregularities on the measurement.
At the end of the day, however, you are most likely to improve your gaging
performance by applying a bit more tender loving care. Gages that have been
serving you well for the past 5 or 10 years are probably a little frayed around
the edges. The only time they were ever looked at were those once-a-year
calibrations. While they still pass good parts, they may not be so good with
tighter tolerances. It may be time to get the gages on a more regular and rigid
inspection schedule.
It’s also a good time to start looking for those enemies of precision gaging
that can steal away a large percentage of your tolerance. On fixed plug gaging,
for example, worn bodies increase clearance and reduce performance. After
measuring thousands of parts and exploring their diameters, contact points can
also become worn. Large worn spots on a pair of contacts can cause two
errors—they can report different sizes than a similar gage with fresh new
contacts, and the flat area can span gaps or imperfections in the part. These
are often the types of errors you would see when two lines are using the same
gaging, but one line is using a newer gage than the other. The gages “see” the
parts differently, and the error is not discovered until the parts are being
assembled, when it’s too late.
Finally, the real enemy in the shop is the environment. Treat the gages better
by wiping them off and blowing them clean more often. Clean the parts as well.
You may want to make wiping the part clean before measurement a required part of
the operator’s measurement process.
With a little more care and tolerance consideration, those old gages may still
be able to meet increased performance requirements based on new part tolerances.